KPN5500-000 - Bar Graph Temperature Controllers
KPN5500-000
- Power supply : 100-240VAC~ 50/60Hz
- Input type_RTD : JPt100Ω, DPt100Ω, DPt50Ω, Cu100Ω, Cu50Ω, Nikel120Ω (6 types)
- Input type_TC : K, J, E, T, L, N, U, R, S, B, C, G, PLII (13 types)
- Input type_Analog : ㆍVoltage: 0-100mV, 0-5 V, 1-5 V, 0-10 V (4 types) ㆍCurrent: 0-20mA, 4-20mA (2 types)
- Control method : ON/OFF, P, PI, PD, PID
- Protection structure : IP65(front panel)
- Control output : Selectable Relay output, Current output, SSR drive output
- Environment_Ambient temperature : -10 to 50℃, storage: -20 to 60℃
Data sheet Print
Power supply | 100-240VAC~ 50/60Hz |
---|---|
Input type_RTD | JPt100Ω, DPt100Ω, DPt50Ω, Cu100Ω, Cu50Ω, Nikel120Ω (6 types) |
Input type_TC | K, J, E, T, L, N, U, R, S, B, C, G, PLII (13 types) |
Input type_Analog | ㆍVoltage: 0-100mV, 0-5 V, 1-5 V, 0-10 V (4 types) ㆍCurrent: 0-20mA, 4-20mA (2 types) |
Control method | ON/OFF, P, PI, PD, PID |
Sampling cycle | 50ms |
Protection structure | IP65(front panel) |
Size | DIN W96×H96mm |
The number of control ouptut | 1 output type(Heating or Cooling type) |
Control output | Selectable Relay output, Current output, SSR drive output |
Option communication output | None |
Option input/output | None |
Environment_Ambient temperature | -10 to 50℃, storage: -20 to 60℃ |
Environment_Ambient humidity | 35 to 85% RH, storage: 35 to 85% RH |
Weight | Approx. 316g(approx. 220g) |
※The 1 output type is heating or cooling output type and the 2 output type is heating & cooling output type.The 1 output type is able to use only one output among relay output, current output, SSR drive output.OUT1 of the 2 output type is fixed as heating output and OUT2 of the 2 output type is fixed as cooling output.If you select the SSR drive output or current output model, you can select the appropriate control output.※Displayaccuracy:◎At room temperature (23℃±5℃)ㆍTC K, J, T, N, E type, below -100℃ / L, U, PLⅡ, RTD Cu50, DPt50: (PV ±0.3% or ±2℃, select the higher one) ±1digitㆍTC C, G and R, S type, below 200℃: (PV ±0.3% or ±3℃, select the higher one) ±1digitㆍTC B type, below 400℃, there is no accuracy standards.◎Out of room temperature rangeㆍRTD Cu50, DPt50: (PV 0.5% or ±3℃, select the higher one) ±1digitㆍRTD R, S, B, C, G: (PV ±0.5% or ±10℃, select the higher one) ±1digitㆍOther sensors: below -100℃, within ±5℃※The weight includes packaging. The weight in parenthesis is for unit only.※Environment resistance is rated at no freezing or condensation.
3D Viewer
* You can check out the 3D Viewer by the CAD button under the product image.
PR materials
Technical dataView more
- No search results
-
- {{ result.parntsBbsCtgryNm }}
- {{ result.bbsCtgryNm }}
{{ result.nationAtchVoList[0].extension }} {{ result.nttSj }}- {{ result.parntsBbsCtgryNm }}
- {{ result.bbsCtgryNm }}
{{ result.nationAtchVoList[0].extension }} {{ result.nttSj }}