BD-100R - Laser Displacement Sensors (Sensor Head and Amplifier Unit)
* Image may differ
BD-100R
- Spot diameter : Near: ≈ 200×200 ㎛Reference: ≈ 220×220 ㎛Far: ≈ 240×240 ㎛
- Resolution : 4㎛
- Reference distance : 98.3 mm
- Max. measurement range : 86.3 to 110.3 mm
- Linearity : ± 0.15% of F.S.
Data sheet Print
Spot diameter | Near: ≈ 200×200 ㎛Reference: ≈ 220×220 ㎛Far: ≈ 240×240 ㎛ |
---|---|
Resolution | 4㎛ |
Reference distance | 98.3 mm |
Max. measurement range | 86.3 to 110.3 mm |
Linearity | ± 0.15% of F.S. |
Temperature Characteristics | ± 0.06% of F.S./℃ |
Power supply | Using power from the amplifier unit. |
Light source | Red semiconductor laser (wavelength: 660nm, IEC 60825-1:2014) |
Light Source_Optical method | Regular reflection |
Light Source_Laser class | Class 1 (IEC/EN), Class I (FDA(CDRH) CFR Part 1002) |
Laser Pulse duration | Max. 2ms |
Light Source_Output | Max. 300㎼ |
Operation indicator | Power indicator: red LED, Laser emission indicator: green LED,NEAR/FAR indicator: green LED |
Insulation resistance | Over 20MΩ (at 500VDC megger) |
Noise immunity | Square shaped noise by noise simulator (pulse width: 1㎲) ±500V |
Dielectric strength | Between the charging part and the case: 1,000 VAC~ 50/60 Hz for 1 minute |
Vibration | 1.5 mm amplitude at frequency of 10 to 55Hz in each X, Y, Z direction for 2 hours |
Shock | 300m/s² (approx. 30G) in each X, Y, Z direction for 3 times |
Environment_Ambient illumination | Max. Incandescent lamp 10,000 lx |
Environment_Ambient temperature | -10 to 50 ℃, Storage: -15 to 60 ℃ (no freezing or condensation) |
Environment_Ambient humidity | 35 to 85 %RH, storage: 35 to 85 %RH (no freezing or condensation) |
Protection structure | IP67 (IEC Standards, except connector of extension cable) |
Material | Case: Polycarbonate, Sensing part: Glass, Cable: Polyvinyl chloride |
Amplifier unit compatibility | BD Series amplifier unit: 1 |
Weight | ≈ 66 g (≈ 228 g) |
3D Viewer
* You can check out the 3D Viewer by the CAD button under the product image.
PR materials
PR materials can be downloaded without login.
Technical dataView more
3D drawings for each detailed model can be checked and downloaded from the model page at the bottom.
- No search results
-
- {{ result.parntsBbsCtgryNm }}
- {{ result.bbsCtgryNm }}
{{ result.nationAtchVoList[0].extension }} {{ result.nttSj }}- {{ result.parntsBbsCtgryNm }}
- {{ result.bbsCtgryNm }}
{{ result.nationAtchVoList[0].extension }} {{ result.nttSj }}