TX4S-B4R - LCD Display PID Temperature Controllers
TX4S-B4R
- Display method : 4-digit 11-segment LCD
- Control method : ON/OFF, P, PI, PD, PID
- Input specification : Thermocouple: K(CA), J(IC), T(CC), R(PR), S(PR), L(IC)RTD: DPt100Ω, Cu50Ω
- Sampling cycle : 50ms
- Control output : Relay (250VAC~ 3A, 30VDC @(=) 3A)
Data sheet Print
Display method | 4-digit 11-segment LCD |
---|---|
Control method | ON/OFF, P, PI, PD, PID |
Input specification | Thermocouple: K(CA), J(IC), T(CC), R(PR), S(PR), L(IC)RTD: DPt100Ω, Cu50Ω |
Sampling cycle | 50ms |
Control output | Relay (250VAC~ 3A, 30VDC @(=) 3A) |
Option output | Alarm 1/2, RS485 comm. |
Power supply | 100-240VAC~ 50/60Hz |
Protection structure | IP50(front panel) |
Display accuracy_RTD | •At room temperature(23℃±5℃):(PV ±0.3% or ±1℃, select the higher one) ±1-digit•Out of room temperature:(PV ±0.5% or ±2℃, select the higher one) ±1-digit |
Display accuracy_Thermocouple | •At room temperature(23℃±5℃):(PV ±0.3% or ±1℃, select the higher one) ±1-digit•Out of room temperature:(PV ±0.5% or ±2℃, select the higher one) ±1-digit |
Hysteresis(adjustable sensitivity) | 1 to 100℃/℉(0.1 to 50.0℃/℉) variable |
Proportional band | 0.1 to 999.9℃/℉ |
Integral time | 0 to 9999 sec |
Derivative time | 0 to 9999 sec |
Control period | 0.5 to 120.0 sec |
Manual reset | 0.0 to 100.0% |
Environment_Ambient temperature | -10 to 50℃, storage: -20 to 60℃ |
Environment_Ambient humidity | 35 to 85% RH, storage: 35 to 85% RH |
Insulation type | Double insulation (mark: @(INS), dielectric strength between primary circuit and secondary circuit: 3kV) |
Weight | Approx. 146.1g(approx. 86.7g) |
※When using the unit at low temperature (below 0℃), display cycle is slow. Control output operates normally.※◎ At room temperature(23℃±5℃)TC R(PR), S(PR) , below 200℃: (PV ±0.5% or ±3℃, select the higher one) ±1-digit, over 200℃: (PV ±0.5% or ±2℃, select the higher one) ±1-digitTC L(IC), RTD Cu50Ω: (PV ±0.5% or ±2℃, select the higher one) ±1-digit◎ Out of room temperature rangeTC R(PR), S(PR): (PV ±1.0% or ±5℃, select the higher one) ±1-digitTC L(IC), RTD Cu50Ω: (PV ±0.5% or ±3℃, select the higher one) ±1-digit※The weight includes packaging. The weight in parenthesis is for unit only.※Environment resistance is rated at no freezing or condensation.
3D Viewer
* You can check out the 3D Viewer by the CAD button under the product image.
PR materials
Technical dataView more
- No search results
-
- {{ result.parntsBbsCtgryNm }}
- {{ result.bbsCtgryNm }}
{{ result.nationAtchVoList[0].extension }} {{ result.nttSj }}- {{ result.parntsBbsCtgryNm }}
- {{ result.bbsCtgryNm }}
{{ result.nationAtchVoList[0].extension }} {{ result.nttSj }}