SFDL2-PM6B-BM20K-T - Safety Flat Type Door Lock Switches

model * Image may differ
CAD

SFDL2-PM6B-BM20K-T

  • Directing opening force : Min. 80N
  • Directing opening distance : Min. 10mm
  • Locking pullout strength : Min. 1,300N
  • Indicator : Solenoid status or contact status (orange, depending on connection)
  • Weight : ≈ 400 g (≈ 490 g)
certmark certmark certmark certmark certmark certmark certmark certmark

Data sheet Print

Data sheet
Directing opening force Min. 80N
Directing opening distance Min. 10mm
Locking pullout strength Min. 1,300N
Operating speed 0.05 to 1m/s
Operating frequency Max. 20/min
Life cycle_Mechanical Min. 1,000,000 operations (20/min)
Indicator Solenoid status or contact status (orange, depending on connection)
Vibration_Malfunction 0.35mm single amplitude at frequency of 10 to 55Hzin each X,Y,Z direction for 10 min
Shock 1,000m/s² (approx. 100G) in each X, Y, Z direction for 3 times
Shock_Malfunction 80m/s² (approx. 8G) in each X, Y, Z direction for 3 times
Environment_Ambient temperature -10 to 55℃, storage: -25 to 65℃
Environment_Ambient humidity 35 to 85% RH, storage: 35 to 85% RH
Protection structure IP67(IEC standerd, except head)
Material Head: zinc or PA, case: PA
Weight ≈ 400 g (≈ 490 g)
Rated load voltage & current Resistive load: 6 A/250 VAC~, 0.6 A/250 VDC@(=)
Inductive load (IEC): AC-15 3 A/240 VAC~, DC-13 0.27 A/250 VDC@(=)
Inductive load (UL): A300, Q300
Dielectric strength_Between the terminals of same polarity 2.5kV
Dielectric strength_Between the terminals of different polarity 4 kV
Dielectric strength_Between each terminal and non-live part 6 kV
Insulation resistance 100MΩ or more (500VDC megger basis)
Contact resistance ≤ 100 mΩ
Life cycle_Electrical ≥ 100,000 operations (250 VAC~/6 A)
Conditional short circuit current 100A
Rated voltage 24 VDC@(=), class 2
Current consumption Supplying power: 0.26A
Normal: max. 0.2A (approx. 3 seconds after supplying power)
Insulation class Class E

3D Viewer

* You can check out the 3D Viewer by the CAD button under the product image.

PR materials

PR materials can be downloaded without login.
  • {{result.bbsCtgryNm}}
    {{result.nttSj}}
    Language selection
    Downloads Preview

Technical dataView more

3D drawings for each detailed model can be checked and downloaded from the model page at the bottom.
  • No search results

Recently viewed product(s)

View more

There are no recently viewed product(s)

Interested product(s)

View more

Compare products

View more

Download history

View more

Product Inquiry