Recommended browsers

Please use Internet Explorer 10 or above for optimal viewing experience on the Autonics website.

When using Internet Explorer 10 or earlier, 3D CAD viewer and screen layout may not be displayed normally.
For ease of use the site, we recommend upgrading to a modern browser.

browser img

SFLA20-68 - Safety Light Curtains (High Performance Type)

model * Image may differ
CAD

SFLA20-68

  • Sensing distance : Short - Long mode (setting switch or atLightCurtain)
  • Short mode : 0.2 to 8 m
  • Long mode : 0.2 to 15 m
  • Detection capability : Ø 20 mm (hand)
  • Number of optical axes : 68
  • Optical axis pitch : 15mm
  • Series connection : Max. 4 SET (≤ 400 optical axes)
certmark certmark certmark certmark certmark certmark certmark

Data sheet Print

Data sheet
Sensing type Through-beam type
Light source Infrared LED(855nm)
Effective aperture angle(EAA) Within ± 2.5 ° when the sensing distance is greater than 3 m for both emitter and receiver.
Sensing distance Short - Long mode (setting switch or atLightCurtain)
Short mode 0.2 to 8 m
Long mode 0.2 to 15 m
Detection capability Ø 20 mm (hand)
Sensing target Opaque
Protective height 1023 mm
Number of optical axes 68
Optical axis pitch 15mm
Series connection Max. 4 SET (≤ 400 optical axes)
Power supply 24 VDC@(=) ±20 %(ripple P-P: ≤10 %)
Current consumption Emitter: ≤106mA, receiver: ≤181mA
Safety related output: OSSD output NPN or PNP open collector
Load voltage : ON - 24 VDC@(=) (except for the residual voltage), OFF - 0 VDC@(=)
Load current : ≤ 300 mA
Residual voltage : ≤ 2 VDC@(=)(except for voltage drop due to wiring)
Load capability: ≤ 2.2 ㎌
Leakage current: ≤ 2.0 mA
Wire resistance of load: ≤ 2.7 Ω
Auxiliary output(AUX 1/2) NPN or PNP open collector
Load voltage: ≤ 24 VDC@(=), Load current: ≤ 100 mA,
Residual voltage: ≤ 2 VDC@(=) (except for voltage drop due to wiring)
Lamp output(LAMP 1/2) NPN or PNP open collector
Load voltage: ≤ 24 VDC@(=), Load current: ≤ 300 mA
Protection circuit Reverse power polarity, reverse output polarity, output short-circuit over-current protection
Safety-related functions Interlock (reset hold), external device monitoring (EDM), muting/override, Blanking (fixed blanking, floating blanking), reduced resolution
General functions Self-test, alarm for reduction of incident light level, mutual interference prevention
Others functions Change of sensing distance, switching to NPN or PNP, external test (light emission stops), auxiliary output (AUX 1, 2), lamp output (LAMP1, 2)
Synchronization type Timing method by RS485 synchronous line
Insulation resistance Over 20MΩ (at 500VDC megger)
Noise immunity The square wave noise (pulse width: 1㎲) by the noise simulator ±240VDC@(=)
Dielectric strength 1,000VAC 50/60Hz for 1 minute
Vibration 10 mm double amplitude at frequency of 5 to 150 Hz, 10 sweeps ni each X, Y, Z direction
Shock 250 m/s² (≈ 25 G), pulse width 6 ms in each X, Y, Z direction for 100 times
Environment_Ambient illumination Sunlight: Max. 10,000lx, Incandescent lamp: Max. 3,000lx (received illumination)
Ambient temperature -30 to 60 ℃, storage: -30 ~ 70 ℃ (no freezing or condensation)
Ambient humidity 35 to 85 %RH, storage: 35 to 95 %RH (non-freezing or non-condensation)
Protection structure IP65, IP67(IEC Standard), IP67G (JEM Standard), IP69K (DIN Standard)
Material Case: Aluminum, Front cover and sensing part: Polymethyl methacrylate, End cap: polycarbonate, Power I/O cable and connector cable: polyurethane (PUR) or polyvinyl chloride (PVC), Y type connector cable: polyvinyl chloride (PVC), lamp output cable and series connector cable: polyurethane (PUR), Top / Bottom adjustable bracket and Top / Bottom bracket: SUS304, Side adjustable bracket and Side bracket: nickel plated Zn
International standards UL 508, CSA C22.2 No. 14, ISO 13849-1 (PL e, Cat. 4), ISO 13849-2 (PL e, Cat. 4), UL 61496-1 (Type 4, ESPE), UL 61496-2 (Type 4, AOPDs), IEC/EN 61496-1 (Type 4, ESPE), IEC/EN 61496-2 (Type 4, AOPDs), IEC/EN 61508-1~-7 (SIL 3), IEC/EN 62061 (SIL CL 3)

※ Current consumption, Response time: It may differ depending on the models. For more information, see the "SFL/SFLA User Manual."
※ Load voltage of Safety related output: The values of load voltage were drawn with PNP output, and in case of NPN output, apply these in reverse.
※ Load current of Safety related output: Be sure that the load current should be greater than 6 mA
※ Residual voltage of Safety related output: The residual voltage was drawn with 300 mA of load current.
※ Auxiliary output, Lamp output: It is the non-safety output. Do not use it for safety purposes.
※ Approved certification protection ratings are IP65 and IP67.
※ The certified models for S-mark and KCs (industrial robot protection device) have the same functional basis

3D Viewer

* You can check out the 3D Viewer by the CAD button under the product image.

PR materials

PR materials can be downloaded without login.
  • {{result.bbsCtgryNm}}
    {{result.nttSj}}
    Language selection
    Downloads Preview

Technical dataView more

3D drawings for each detailed model can be checked and downloaded from the model page at the bottom.
  • No search results

Related product(s)

Used together with

Recently viewed product(s)

View more

There are no recently viewed product(s)

Interested product(s)

View more

Compare products

View more

Download history

View more

Product Inquiry