MP5W-48 - High Performance Digital Pulse Meters
MP5W-48
- Display method : 5-digit 7-segment LED
- Character height : 14mm
- Max. display Range : -19999 to 99999
- Measurement : 16 operation modes: Frequency, Revolutions, Speed, Cycle, Time, Ratio, Density, Error, Length measurement, Interval, Accumulation, Addition/Subtraction, etc.
- Measurement range : 0.0005Hz to 50kHz, 0.01 to max. of each time range, 0 to 99999, -19999 to 99999
- Input method : Voltage input(PNP), No-voltage input(NPN)
- Power supply : 100-240VAC~ 50/60Hz
Data sheet Print
Display method | 5-digit 7-segment LED |
---|---|
Character height | 14mm |
Max. display Range | -19999 to 99999 |
Measurement | 16 operation modes: Frequency, Revolutions, Speed, Cycle, Time, Ratio, Density, Error, Length measurement, Interval, Accumulation, Addition/Subtraction, etc. |
Measurement range | 0.0005Hz to 50kHz, 0.01 to max. of each time range, 0 to 99999, -19999 to 99999 |
Input method | Voltage input(PNP), No-voltage input(NPN) |
Power supply | 100-240VAC~ 50/60Hz |
External Power Supply | Max. 12VDC @(=) ±10% 80mA |
Output_Main Output(Comparative Value) | NPN open collector (HH, H, GO, L, LL) |
Output_Sub Output(Display Value) | RS485 communication |
Input frequency | ·Solid state input 1: max. 50kHz (pulse width: min. 10㎲)·Solid state input 2: max. 5kHz (pulse width: min. 100㎲)※For F7, F8, F9, F10 operation mode, max. 1kHz (pulse width: min. 500㎲)·Contact input: max. 45Hz (pulse width: min. 11ms) |
Measurement range | ·Operation mode F1, F2, F7, F8, F9, F10 : 0.0005Hz to 50kHz·Operation mode F3, F4, F5, F6 : 0.01 to max. of each time range·Operation mode F11, F12, F13, F16 : 0 to 99999·Operation mode F14, F15 : -19999 to 99999 |
Measurement accuracy | ·Operation mode F1, F2, F7, F8, F9, F10 : F.S.±0.05%rdg±1-digit·Operation mode F3, F4, F5, F6 : F.S.±0.01%rdg±1-digit |
Prescale function | Direct input method (0.0001×10@(^-9) to 9.9999×10@(^9)) |
Environment_Ambient temperature | -10 to 50℃, storage: -20 to 60℃ |
Environment_Ambient humidity | 35 to 85% RH, storage: 35 to 85% RH |
Weight | Approx. 334g (approx. 210g) |
Protection structure | IP54 (front part, IEC standard) |
※Hysteresis: Setting range will vary depending on the decimal point.※The weight includes packaging. The weight in parenthesis is for unit only.※Environment resistance is rated at no freezing or condensation.※Sold separately: Hirose connector socket (HIF3BA-20D-2.54R)
3D Viewer
* You can check out the 3D Viewer by the CAD button under the product image.
PR materials
Technical dataView more
- No search results
-
- {{ result.parntsBbsCtgryNm }}
- {{ result.bbsCtgryNm }}
{{ result.nationAtchVoList[0].extension }} {{ result.nttSj }}- {{ result.parntsBbsCtgryNm }}
- {{ result.bbsCtgryNm }}
{{ result.nationAtchVoList[0].extension }} {{ result.nttSj }}
Used together with
-
BEST
SCM Series
The SCM series communication converters are available in various types, to offer easy signal conversion and flexibility for building diverse systems. Wireless, USB-RS485, RS232C-RS485, and USB-Serial converters are available.
-
UPGRADE BEST
DAQMaster
DAQMaster is a comprehensive device management software used to configure parameters, monitor real-time data, and store data with communication supported devices from Autonics. Simple GUI control allows easy and convenient management of parameters and data monitoring of multiple devices. DAQMaster is available in Standard (free) and Pro (paid) versions for PCs.